Technical notes
Questions we meet in the field and how we solve them: serialization, predictive maintenance, data and regulation.
- 3 min readMTBF, MTTR and availability: three numbers, three different questionsMTBF says how often a machine fails, MTTR how quickly it comes back, availability what share of the time the line can produce. We calculate all three from one example, show which decision each one supports, and list the four most common mistakes.
- 3 min readBearing life L10: what it says and what it does not, with load, speed and reliabilityFrom the catalogue dynamic load rating to the basic rating life, then to the reliability and operating-condition adjustment: we calculate a bearing's expected life step by step, show why a small increase in load shortens life so much, and list the questions L10 does not answer.
- 3 min readPareto of downtime causes: 80/20 is not a law, it is a starting pointWe rank one month of downtime records by cause and work out the cumulative share. The example deliberately does not follow 80/20: five of eight causes make up 86.7% of the total. We show how to choose the threshold, how record quality distorts the result, and what comes after Pareto.
- 3 min readThe true cost of unplanned downtime: how to calculate lost hours, repair and the payback of predictive maintenanceThe cost of one stoppage is more than the repair invoice. We walk through lost production hours, repair and a realistic estimate of what early warning saves in one worked example, and show which assumption moves the result most.
- 3 min readSix common mistakes on medical device UDI labelsPackaging levels, changes that require a new UDI-DI, confusing Basic UDI-DI with UDI-DI, missing production identifiers, labels that don't match the barcode and unmeasured print quality: the most common UDI mistakes for medical devices.
- 3 min readSix ways the case–pallet relationship breaks in aggregationRejected packs, partial cases, sampling, manual handling, double assignment and pallet breakdown: the most common situations in which aggregation records drift from physical content, and how to prevent them on the line.
- 2 min readGaps and bad records in SCADA data: what to do before modellingTimestamps, gaps, frozen sensors, physically impossible values, curtailment and maintenance periods, sensor replacement: what to check in SCADA data before building a predictive maintenance or power forecasting model.
- 3 min readHow to read and validate a GS1 code: from raw data to field-by-field checksThe raw text a scanner returns, the invisible separator, field lengths, calculating the GTIN check digit by hand and checking the date: a step-by-step guide to validating a GS1 code.
- 2 min readHow to calculate OEE, and the six most common mistakesThe product of availability, performance and quality; a step-by-step example on a 450-minute shift and six common mistakes that distort the OEE figure.
- 3 min readSPC and Cpk: when a control chart raises an alarm and when a process is capableCalculating I-MR control limits, the logic of the Nelson rules, the difference between control limits and specification limits, and why Cpk can be low in a ten-point example even while the process is in control.
- 3 min readFive common errors in pharma serialization codes and how to catch them on the lineMissing separators, wrong check digits, date format mix-ups, duplicate serial numbers and disallowed characters: the most frequent errors in pharma DataMatrix codes and how to prevent each one on the line.
- 2 min readStarting predictive maintenance without labeled failure dataPredictive maintenance does not need a dataset of labeled past failures. Learning normal behavior, linking alarms to a physical fault class and collecting labels along the way is a sound start.
- 2 min readAudit trails for 21 CFR Part 11: what to record and howOn the software side, FDA's 21 CFR Part 11 requirements for electronic records and signatures show up most in the audit trail. What to record, immutability, retention and a short checklist for electronic signatures.
- 3 min readEarly failure warning from vibration data: the ISO 20816 logic and a general approachWhat the vibration severity zones tell you, why you should look at your own baseline and trend rather than a single limit, the acceleration-velocity conversion and common mistakes when setting alarms.
- 3 min readChoosing thresholds for SCADA data quality checks: gaps, frozen values, out-of-rangeCalculating expected record count and coverage from the logging interval, the window length for frozen values, setting physical ranges and how to read the result of a check.
- 3 min readSample size in A/B testing and five common misconceptionsThe sample needed per group from power, significance level and minimum detectable difference, the 5% to 6% example, and misconceptions such as stopping early and multiple comparisons; a short note on survey samples.
- 3 min readCommon cron expression mistakes and time zone trapsDay-of-month and day-of-week combining with OR, step values resetting at the top of the hour, the 31st-day trap, UTC versus local time and jobs that are skipped or run twice at daylight saving changes.
- 3 min readUsing JWT correctly: common security mistakesA JWT is signed, not encrypted; verifying the signature on every request, the alg and expiry fields, where to store it and the revocation problem: eight mistakes to avoid when designing an API.
- 3 min readUPS sizing: VA versus W, power factor and how to calculate runtimeConverting VA to W, the rated power margin, runtime from battery energy and the capacity needed for a target time: a step-by-step UPS calculation on a 300 W load.
- 3 min readCIDR and subnet planning: summarisation, alignment and overlapAddress count from the prefix length, when two networks can be summarised into one block, overlap checking and common mistakes in the address plan when building a VPN or cloud network.